Electric Parameter
|
AC input
|
Input Voltage range:
|
90~264Vac
|
Reted input voltage:
|
100~240Vac
|
InputFrequency Range:
|
47~62hz
|
Input current max:
|
3A
|
Inrush current:
|
35A Max/240V
|
Efficiency:
|
>87%
|
No load Input power
|
<0.5W
|
Leakage current:
|
<0.25mA/240V
|
DC output
|
Max charging voltage:
|
29.2V
|
Output voltage tolerance:
|
5%
|
Max charging current:
|
0~3A
|
Ripple and noise:
|
<250mVp-p
|
Charging mode:
|
3- stage, CC,CV,trickle charging
|
Cut off current when charged full
|
Optional
|
LED indicator
|
Charging: Red, Charged full: Green
|
Charging current when charged full
|
1A
|
Protection
|
Over current protection
|
PASS
|
Over voltage protection
|
Short circuit protection
|
Over Temp protection
|
Anti-flow protection
|
Environment
|
Operating Temp:
|
0℃~+45℃
|
Storage Temp:
|
-30℃~+70℃
|
Relative Humidity:
|
10%~90%
|
Vibration and shock
|
Meet MIL-STD-810D
|
Safety
|
Safety standard
|
EN60950,EN61558,EN60335
|
EMC/EMI
|
Meet FCC CLASS B,EN55022 CLASS B.
|
EMS
|
EN61000-4-2
|
EN61000-4-3
|
EN61000-4-4
|
EN61000-4-5
|
A Harmonic source
|
Pass
|
HI-pot: Primary to Secondary
|
3KVAC,5mA,60s
|
Drop Test
|
As per UL regulation
|
Burning test
|
100%,4-5 hours
|
Life
|
MTBF
|
50000 hours
|
Warranty
|
3 years
|