Electric Parameter |
|||
AC input |
Input Voltage range: |
90~264Vac |
|
Reted input voltage: |
100~240Vac |
|
|
InputFrequency Range: |
47~62hz |
|
|
Input current max: |
5A |
|
|
Inrush current: |
60A Max/240V |
|
|
Efficiency: |
>90% |
|
|
No load Input power |
<0.5W |
|
|
Leakage current: |
<0.75mA/240V |
|
|
DC output |
Max charging voltage: |
42V |
|
Output voltage tolerance: |
5% |
|
|
Max charging current: |
0~8A |
|
|
Ripple and noise: |
<300mVp-p |
|
|
Charging mode: |
3- stage, CC,CV,trickle charging |
|
|
Cut off current when charged full |
Option |
|
|
LED indicator |
Charging: Red, Charged full: Green |
|
|
Charging current when charged full |
0.8A |
|
|
Protection |
Over current protection |
PASS |
|
Over voltage protection |
|
||
Over current protection |
|
||
Short circuit protection |
|
||
Reverse polarity protection |
|
||
Over Temp protection |
|
||
Anti-flow protection |
|
||
Environment |
Operating Temp: |
-20℃~+45℃ |
|
Storage Temp: |
-30℃~+70℃ |
|
|
Relative Humidity: |
10%~90% |
|
|
Vibration and shock |
Meet MIL-STD-810D |
|
|
Safety |
Safety standard |
EN62368,EN61558,EN60335 |
|
EMC/EMI |
Meet FCC CLASS B,EN55022 CLASS B. |
|
|
EMS |
EN61000-4-2 |
|
|
EN61000-4-3 |
|
||
EN61000-4-4 |
|
||
EN61000-4-5 |
|
||
A Harmonic source |
Pass |
|
|
HI-pot: Primary to Secondary |
3KVAC,5mA,60s |
|
|
Drop Test |
As per UL regulation |
|
|
Burning test |
100%,4-5 hours |
|
|
Life |
MTBF |
50000 hours |
|
Warranty |
3 years |
|
Model Name | Rated output voltage range (VDC) | Rated output current range (mA) | Max. output power (W) |
XSECxxxyyyyzz, XSGxxxyyyyzz, XSExxxyyyyzz, XSECxxxyyyyyzz, XSGxxxyyyyyzz, XSExxxyyyyyzz, XSECxxxyyyy, XSGxxxyyyy, XSExxxyyyy, XSECxxxyyyyy, XSGxxxyyyyy, XSExxxyyyyy |
12.0-16.8 | 10000-20000 | 292 |
16.9-23.9 | 10000-18000 | 330 | |
24.0-38.0 | 9000-15000 | 378 | |
38.1-58.0 | 5500-9440 | 360 | |
58.1-88.0 | 4000-6200 |
360 |
we will contact you within 24 hours.